Generally many startups who establish their offices make the most common mistake for choosing air conditioning by dealing with multiple outdoor units for every different cabin or zone. Seriously why do we need individual outdoor units when we deal with each indoor unit by single in the Central AC system. You may not get all of it, no worry let me brief you how single outdoor with multiple indoor units possible with Central AC for Office and its cost saving benefits.
Commercial Offices dedicated areas are usually large in meters as compared to residential building and it divides into many different cabins and zones that’s why a single indoor inverter or ac unit couldn’t have potential to manage cool air around whole sector and multiple indoor units or different zoning ahu takes place here but many of commercial firms who set up not MNC range building area can’t cross cut the cost for air conditioning system by implement Central AC for Offices and Make big mistake. Let me show why :
There are multiple indoor units who work continuously for office working hours. So, when I say that single outdoor is enough then it could be questionable for everyone. The human brain gets many queries like - Is that system failure possible, it may take more electricity, that thing may cause an electric shotcircuit, etc. All things have possibility but from many decades it just remains as theories there Least cases comes about issues which we just discuss. Other Hand that method or system type was highly recommended by HVAC consultants for reducing cost of the Air System.
Companies and Institutes where multi-split ac quantity would be 5-6 was easily handable by my central air conditioning system. Their Evaculator are highly knowable for their continuous regulation of Heat outdoors. One outdoor unit connected by different indoor via refrigerant piping or ducts and here indoor units could work independently and individually for their zones. Basically they follow circulation which are :
Indoor units take warm air from the building zones and rooms.
Then it is filtered by the purification system of the central air system.
Evaporator coil absorbs whole heat from air and by absorbing heat the refrigerant evaporates.
Chilled and Fresh Air now ready for distribution by blowers and fans.
Hot Refrigerants pass through the condenser and Throughout by Outdoor unit.
Here in a multi-split air conditioning system the process is the same and all condenser or refrigerant pipes would be attached with a high power single Outdoor unit.
Energy Saving : There are only single outdoor units present so energy would not expend much as compared to individual outdoor units for indoor ones.
Individual Control on Indoor unit : For the Zoned or Cabins where split ac could be implemented don’t affect outdoor unit by their switch on off circumstance.
Space Removing : Multi outdoor takes much space as compared to high power single outdoor unit in central ac for offices.
Cost Effective : Automatically everyone shows a multi outdoor unit is way cost for setup as compared to Single High Power Unit that’s one other benefit of Central Aircon with Single Outdoor only.
For taking advantage of Single High Power Outdoor Unit in Central AC you may remind two major precautions - Outdoor capacity & size would be determined on behalf of multi-splits indoor, & other thing is careful planning of refrigerant piping and zoning for best performance. For not getting in trouble while installation you may hire an Installation Contractor like Ventac Aircon who has 30+ Years Experience with 700+ Installation Excellence.
It is much cheaper to install, is energy saving, occupies no outdoor space and it is possible to control it by zone without having a separate outdoor unit to each indoor unit.
Large capacity outdoor unit are linked to various indoor units by use of refrigerant piping. It effectively controls all-connected indoor units in heat removal when they run independently although at the same time.
Dedicated advantages are that the initial cost of equipment may be purchase of a single more powerful outdoor unit rather than a significant number of smaller ones, cost of installation may be simplified and in terms of energy savings the system operating costs are reduced greatly by its effectiveness.
No. The indoor units (that serve a particular cabin or zone) can be switched or operated independently, this means that the users can set the temperature he/she wants without influencing other areas.
Accurate matching of the exterior unit to the total capacity of the interior units and professional design/laying of the network of refrigerant pipes play a very important role in guaranteeing efficiency and applicability. It is advisable to contract those skilled in the job, such as Ventac Aircon.