Major Role of Precision AC for IT Company Server Room


Role of Precision AC for IT Company

IT Company where collection of data from user to server continuous 24/7 hours everyday role of precision ac for IT like those could be very too much obvious & salient. Let’s recall the all major to small functions & features of Precision Air Conditioning for IT Hub.


Why Precision AC Important for Server Room

For IT Companies or Server Room where the large amount of user traffic is an obvious thing. That’s why the server where the data of user intent, cookies, privacy, etc are stored work non stop without break for a single second. Continuous working creates heat by the motion & that thing creates the warning of blast, melting of parts, or sudden system failure. Role of Precision AC for IT now came to origin where its installation in the data center removes all warnings by its features or functions where it contains a specific measure of temperature for the whole time.


General Features of Precision Air Conditioner

  1. Compact Temperature Control : Precision Air Conditioners are highly designable for managing a room or zone temperature in a narrow specific range ±1°C - ±5°C for Server Rooms.

  2. Air Filtration & Circulation : Not even a single dust or pollen considered to regulate in the server room & precision ac for IT company circulates air to every single part of the server room.

  3. Humidity Regulates : These server room ac units control humidity of the zone within recommended range ( 40 - 60% RH ) which prevents conversion, corrosion, static electricity, etc. That feature specially protects the hardware of the server.

  4. Equipment Safety : As told in the last point it regulates humidity, that major feature helps to increase the lifespan of servers & save them from the unfortunate disaster.

  5. Energy Efficient : Server Room came into range of small to large size and power consumption became a big problem of free use but with precision ac for IT companies it is considered to be solved because this range came with salient features of energy efficient cooling.

  6. Multiple form of Cooling : Precision Air conditioner available in air-cooled, water cooled, chilled water system & feature dual cold source setups for redundancy and energy efficiency.


Server Room Friendly Function of Precision AC

  1. Efficient Air Distribution : They deliver a consistent, high-volume airflow in order to remove hotspots in the areas surrounding the crowded server racks and to ensure that all the components get proper cooling.

  2. N+1 Redundancy : Redundancy (N+1 configuration) is typically used to make sure that cooling is not interrupted when one of the units malfunctions.

  3. Reduce Heat : It regulates air distribution continuously & reduces the heat from the server room.

  4. Non Stop Working : Servers are active 24/7 hours that’s why a precision air conditioner came with the function of non stop working.

  5. High Sensible Heat Ratio : Sensible heat generated by electronics was engineered to be managed in precision ACs which are much more effective in removing the heat generated by servers compared with normal comfort ACs.

  6. Remote Management : Several precision AC systems can be remotely monitored/troubleshooted, which facilitates proactive maintenance and less response time in case of emergency.


Working Principle & Process of Precision AC for IT


  1. Warm Air Intake

    1. Carry Highly Sensible Heat from the Server & reduce load from the IT Equipment.

  2. Evaporator Cooling

    1. Then air passes through the cold evaporator, Refrigerant Inside the Coil absorbs the heat.

  3. Compressor Operation

    1. Vaporized Refrigerant is compressed now & it increases pressure & temperature for heat rejection.

  4. Heat Rejection

    1. Now extreme heated refrigerant moves towards the condenser & it goes through outside the server room to air, water or chilled water.

  5. Refrigerant Expansion

    1. A refrigerant expansion valve controls the flow of refrigerant gas so as to optimize temperature and maintain constant supercharge.

  6. Humidity Control

    1. Sophisticated sensors track the temperature and humidity. Fine-adjusting the compressor speed, fan speed and the position of the expansion valve, the strict conditions (usually within +1C and 40-55 RH) are kept with the help of algorithms (PID or adaptive).

  7. Air Filtration

    1. Precision AC for IT Company removes every single pollen & dust & prevents sensitive equipment of Server.

  8. Redundant operation

    1. Data Center HVAC System working 24/7 hours continuously often in N+1 Redundancy ( Backup Unit ) ensures the constant cooling.

  9. Intelligent Response

    1. Self-diagnostic sensors identify abnormalities, issue alarms, and automatically rectify the problems and this guarantees maximum reliability.

And now that’s all the complete process and principle of Working & Role of Precision AC for IT Company Server Room. And for complete quotation & consultation of air conditioning units for server room or HVAC Services also contact us here.